Izdelki za mac ventili za zrak (10)

Ventili - Zaščita pred prenapolnjenjem

Ventili - Zaščita pred prenapolnjenjem

Valves - Overpressure protector
Tip 7080 – Tri-vejni ventil iz bronze - Tri-vejni ventili

Tip 7080 – Tri-vejni ventil iz bronze - Tri-vejni ventili

Pneumatic actuated threeway valve for neutral media made from bronze, perfect fit for high cycling applications. Whitworth pipe thread NPT thread Limit switch Pilot valve Manual override . . . Piston actuator of Brass (chrome plated) Stainless steel Polymer Stainless steel diaphragm actuator Size:DN 15 - DN 40 Pressure:PN 16 Material:Bronze RG5 Media temperature:-30 °C to +170 °C Application:Gases, vapours, fluids Versions:Different control functions such as distributing and mixing function…
IMAV Ventili za omejevanje tlaka z navojem - IMAV Navojni ventili serije IDBD

IMAV Ventili za omejevanje tlaka z navojem - IMAV Navojni ventili serije IDBD

IMAV DruckbegrenzungsEinschraubventile in den NG 6 und 10. Direkt gesteuert und individuell einstellbar.
Stiskalne ventile za higienske procese (Serija VMCE)

Stiskalne ventile za higienske procese (Serija VMCE)

Aseptische und hygienische Quetschventile der Serie VMCE. Individuelles Baukastensystem nach Ihren Anforderungen. Nennweiten: DN 10 - DN 100 In-Place Reinigungsmöglichkeiten: CIP, SIP, teilweise molchbar. EHEDG-Zertifizierung: Typ EL Klasse 1, Typ EL Aseptik Klasse 1 Gehäuse und Anschlussmaterial: Edelstahl
Co-ax Ecd-h | Pcd-h Visokotlačne Stranske Ventili - Neposredno delujoči ali zunanje nadzorovani ventili

Co-ax Ecd-h | Pcd-h Visokotlačne Stranske Ventili - Neposredno delujoči ali zunanje nadzorovani ventili

The lateral highpressure valves are valves with two or three connections and two switching positions. The pressure range extends from vacuum up to 500 bar. In this type of construction, the valve drive is not arranged coaxially, but laterally.
Co-ax A | Kb | Kbs Visokotlačne koaksialne ventile - Ventili z neposrednim delovanjem

Co-ax A | Kb | Kbs Visokotlačne koaksialne ventile - Ventili z neposrednim delovanjem

Coaxial highpressure valves are valves with two connections and two switching positions. The pressure range extends from vacuum up to 400 bar. The wall thicknesses for the valve housing and head tube as well as the selection of the seals and the retaining screws are specially designed for high pressure applications. This series is typically used in gas filling stations and test benches, in compressor and hydraulic systems and in washing machines. The KB valve types have a special feature They do not require dynamic plastic seals and can be used in cryogenic application.
Tip 7078 – Stiskalni ventil - Tipi

Tip 7078 – Stiskalni ventil - Tipi

The pinch valve is non sensitive by contaminated, granulated, viscous, doughy and aggressive media. Furthermore it is (depending on the tube material) suitable for sanitary and aseptic applications because of the FDA approval. Size:DN 15 - DN 50 Pressure:PN 6 Material:Stainless steel 1.4408 Media temperature:-40 °C to +160 °C
Ventili - Regulacijski in Zaporni Ventil AVO/AVM

Ventili - Regulacijski in Zaporni Ventil AVO/AVM

Valves - Regulation- & shut-off valve AVO/AVM
Certificirani Ventili Co-ax | Tüv - MK (DR) | FK (DR) TÜV

Certificirani Ventili Co-ax | Tüv - MK (DR) | FK (DR) TÜV

Tested valves are typetested solenoid valves with two or three connections and two switching positions. These are safety shutoff valves in the basic closed position. The type examination ensures that, in the event of a drop in voltage, all valves seal closed within one second and thus reliably shut off the fuel supply (safety valve).
Certificirani ventili Co-ax | Atex - MK (DR) | FK (DR) | KB | KBS ATEX

Certificirani ventili Co-ax | Atex - MK (DR) | FK (DR) | KB | KBS ATEX

Tested valves are typetested solenoid valves with two or three connections and two switching positions. These are safety shutoff valves in the basic closed position. The type examination ensures that, in the event of a drop in voltage, all valves seal closed within one second and thus reliably shut off the fuel supply (safety valve).